It utilizes the Doppler effect, establishing a relationship between the frequency difference of transmission/reception and flow velocity. It also measures the time difference for liquid level detection and uses ambient temperature measurement to correct the speed of ultrasonic propagation.
| Flow rate range | 0~10m/s |
| Flow rate resolution | 0.001m/s |
| Velocity Accuracy | 0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity |
| Ultrasonic Level Range | 6.5m |
| Ultrasonic Level Accuracy | 0.001m |
| Hydrostatic level range | 0~10m |
| Hydrostatic level accuracy | ±0.1%FS |
| Temperature range | -20~60ºC |
| Material | Metal, POM, Rubber |
| Protection class | IP68 |
| Communication Interface | RS485, Modbus |
| Work pressure | Max 6Bar |
The mainframe supports embedded and wall-mounted installation (Dimensions: 176 x 150 x 86mm).